Kendall SCD 700 Series Manual: A Comprehensive Guide
Welcome to the comprehensive guide for the Kendall SCD 700 series, a sequential compression system designed for effective deep vein thrombosis (DVT) prevention. This manual provides crucial information, operating instructions and troubleshooting tips. Service technicians should familiarize themselves with this guide and operating principles.
The Kendall SCD 700 system, a product of Cardinal Health (formerly Covidien), represents a significant advancement in pneumatic compression therapy. This system is engineered to deliver sequential, gradient compression, enhancing blood flow and preventing deep vein thrombosis (DVT) in patients. The Kendall SCD 700 is designed for ease of use, and patient comfort, while providing a reliable method for DVT prophylaxis.
This system incorporates Covidien’s patented Vascular Refill Detection (VRD) technology. This ensures fully customized and efficacious compression therapy. The Kendall SCD 700 system offers features such as automatic garment detection which facilitates ease of use. The user interface is simple with intuitive controls and clear display. This makes it easy for healthcare providers to set up and monitor the therapy.
The Kendall SCD 700 system ensures that patients receive optimal care and protection. This minimizes the risk of DVT-related complications. The system is compatible with both Kendall SCD Comfort and Express compression garments. This provides flexibility in selecting the appropriate garment for each patient’s needs. With its advanced features and user-friendly design, the Kendall SCD 700 system is a valuable tool in preventing DVT. It promotes better patient outcomes.
Indications and Therapeutic Use of the Kendall SCD 700
The Kendall SCD 700 system is indicated for patients at risk of developing Deep Vein Thrombosis (DVT). This includes those undergoing surgical procedures, individuals with limited mobility and patients with certain medical conditions. The system is designed to enhance blood circulation in the lower limbs. This helps to prevent the formation of blood clots.
Therapeutic use involves applying sequential compression to the legs. This mimics the body’s natural muscle contractions. This promotes venous return and reduces venous stasis. The Kendall SCD 700 is suitable for use in various clinical settings. This includes hospitals, surgical centers and long-term care facilities. The system is intended for use on adult patients. Garments should be selected with care to ensure correct fit and efficacy.
The Kendall SCD 700 system supports improved patient outcomes. It minimizes the risks associated with DVT. It is also easy to use, and has adjustable pressure settings. It provides customized therapy based on individual patient needs. Regular monitoring and adherence to the guidelines ensures optimal therapeutic benefits. Healthcare professionals should follow the instructions provided in the manual. This ensures the safe and effective use of the Kendall SCD 700 system.
Components of the Kendall SCD 700 System
The Kendall SCD 700 system comprises several key components that work together to deliver effective sequential compression therapy. The primary component is the controller unit. This sophisticated device regulates the pressure and timing of the compression cycles. It ensures consistent and reliable performance. The controller features an intuitive interface. It also has user-friendly controls that allow healthcare professionals to easily adjust settings and monitor therapy.
The system also includes compression garments. These garments are available in various sizes to accommodate different patient needs. These garments are designed to fit securely around the patient’s legs. They ensure targeted compression is delivered to the appropriate areas. Connecting tubes are included to connect the garments to the controller, facilitating the transfer of air pressure.
Additionally, the Kendall SCD 700 system comes with a power cord for connecting to a power source. The system includes comprehensive documentation. This includes an operation and service manual. This manual provides detailed instructions on setup, operation, troubleshooting, and maintenance. All components are designed for durability and ease of use. This ensures that the Kendall SCD 700 system provides reliable performance and supports optimal patient care.
Setting Up the Kendall SCD 700 System
Setting up the Kendall SCD 700 system involves several key steps to ensure proper functionality and patient safety. First, carefully unpack all the components, including the controller, compression garments, connecting tubes, and power cord. Inspect each item for any signs of damage before proceeding. Place the controller on a stable, flat surface near a power outlet, ensuring adequate ventilation around the unit.
Next, connect the power cord to the controller and plug it into the power outlet. Then, attach the connecting tubes to the designated ports on the controller. Select the appropriate size compression garments for the patient and apply them securely around the patient’s legs, ensuring a snug but comfortable fit. Verify that the garments are correctly positioned according to the manufacturer’s instructions.
Connect the compression garments to the connecting tubes. Double-check all connections to ensure they are secure and free from kinks or obstructions. Finally, power on the controller and perform a system check to confirm that all components are functioning correctly. Refer to the operation manual for detailed instructions and troubleshooting tips if any issues arise during setup. Proper setup is crucial for effective DVT prevention.
Operating Instructions: A Step-by-Step Guide
To effectively operate the Kendall SCD 700 system, follow these step-by-step instructions carefully. Begin by ensuring the system is properly set up, with all components connected securely. Verify that the correct size compression garments are applied to the patient’s legs, ensuring a snug but comfortable fit. Once the garments are in place, turn on the Kendall SCD 700 controller using the power switch located on the device.
Next, select the appropriate therapy mode based on the patient’s specific needs and the healthcare provider’s recommendations. The system typically offers various modes, such as sequential compression or intermittent compression. Adjust the pressure settings according to the prescribed parameters, ensuring they are within the recommended range for the patient’s condition. Monitor the patient closely during the initial therapy session to assess their tolerance and response to the compression.
Throughout the operation, regularly check the garments for proper inflation and deflation, ensuring consistent and effective compression. If any issues arise, such as discomfort or alarms, immediately address the problem and consult the troubleshooting section of the manual. Always follow established protocols and guidelines for operating the Kendall SCD 700 system to ensure patient safety and optimal therapeutic outcomes. Proper operation is essential for preventing deep vein thrombosis.
Garment Selection and Verification
Proper garment selection is crucial for the effective operation of the Kendall SCD 700 system. Begin by assessing the patient’s leg circumference to determine the appropriate garment size, consulting the sizing chart provided by the manufacturer. Ensure the selected garments are compatible with the Kendall SCD 700 system, such as the Kendall SCD Comfort compression sleeves or Kendall SCD Express compression sleeves. Once the garments are chosen, visually inspect them for any signs of damage, wear, or contamination, replacing them if necessary.
Before applying the garments, explain the procedure to the patient and ensure their comfort and understanding. Position the garment correctly on the patient’s leg, aligning it with anatomical landmarks and ensuring proper coverage of the calf and thigh, if applicable. Secure the garment using the provided fasteners, ensuring a snug but comfortable fit that does not restrict circulation or cause skin irritation. After application, verify that the garment is properly connected to the Kendall SCD 700 controller, ensuring secure tubing connections.
Finally, confirm the garment’s functionality by initiating a test cycle and observing the inflation and deflation sequence. Check for any leaks, uneven compression, or other issues that may compromise the therapy’s effectiveness. Regularly monitor the garments during use to ensure they remain properly positioned and functional, making adjustments as needed to maintain optimal therapeutic outcomes. This careful process will ensure that the Kendall SCD 700 provides effective compression therapy.
Troubleshooting Common Issues
When operating the Kendall SCD 700 system, several common issues may arise. One frequent problem is the system displaying error messages or alarms. Begin by consulting the error code list in this manual to identify the specific issue. Ensure that all tubing connections are secure and free from kinks or obstructions. Verify that the compression garments are correctly applied and properly connected to the controller. A loose connection can interrupt the intended compression therapy.
Another common issue is the garments failing to inflate or inflate unevenly. Inspect the garments for any tears, punctures, or leaks. Ensure that the air pressure settings are correctly configured according to the physician’s orders. If the system still malfunctions, try power cycling the device by turning it off and then back on. Regularly check the power cord to ensure it’s firmly plugged into a functioning outlet.
If the Kendall SCD 700 system continues to experience issues, consult the detailed troubleshooting section of this manual for further guidance. If the problem persists, contact qualified biomedical equipment technicians for professional repair. Always document any troubleshooting steps taken and the results obtained. Never attempt to repair the device yourself unless you are a trained and certified technician. Proper maintenance and regular inspections can prevent many common problems, ensuring continuous and reliable operation of the Kendall SCD 700 compression system.
Fault Conditions and Troubleshooting
The Kendall SCD 700 system is designed with safety features that trigger fault alerts when operational issues arise. Understanding these fault conditions is crucial for effective troubleshooting. Common fault indicators include error codes displayed on the controller screen, accompanied by audible alarms. These alerts can signal a variety of problems, such as low pressure, high pressure, disconnected garments, or system malfunctions.
When a fault condition occurs, immediately refer to the fault code section in the Kendall SCD 700 series operation and service manual. This section provides detailed descriptions of each fault code and recommended troubleshooting steps. Start by verifying that all connections are secure, including the tubing and garment connectors. Inspect the compression garments for any damage, such as tears or leaks, which could affect the system’s ability to maintain proper pressure.
If the fault persists after checking the connections and garments, try resetting the system. Turn off the controller, wait a few seconds, and then turn it back on. If the fault continues to appear, more advanced troubleshooting may be required. This could involve checking the air pump, pressure sensors, or other internal components. For these types of issues, it is recommended to contact a qualified service technician. Always document the fault code, the troubleshooting steps taken, and the results obtained to aid in the repair process.
Maintenance and Service Guidelines
Proper maintenance is essential to ensure the reliable operation and longevity of the Kendall SCD 700 sequential compression system. Regular cleaning should be performed using a soft, damp cloth and a mild detergent. Avoid harsh chemicals or abrasive cleaners, as these can damage the system’s exterior. The compression garments should also be cleaned regularly according to the manufacturer’s instructions to prevent the buildup of bacteria and maintain hygiene.
Periodically inspect the tubing and connectors for any signs of wear, cracks, or leaks. Replace any damaged components to prevent performance degradation. The air filters should be checked and replaced as needed to ensure optimal airflow and prevent dust from entering the system. It is recommended to establish a routine maintenance schedule to track cleaning, inspections, and parts replacements.
For more complex repairs or servicing, it is important to contact a qualified service technician who is familiar with the Kendall SCD 700 series. Unauthorized repairs can void the warranty and potentially damage the system. Service technicians should refer to the service manual for detailed instructions and troubleshooting procedures. When returning the controller for service, ensure it is properly packaged to prevent damage during transit. Include a detailed description of the issue and any relevant error codes to assist the service team in diagnosing and resolving the problem efficiently.
Returning the Controller for Service at Covidien
If your Kendall SCD 700 controller requires service beyond basic troubleshooting, it may need to be returned to Covidien (now Cardinal Health) for expert attention. Before initiating the return, contact Covidien’s technical support to discuss the issue and obtain a Return Merchandise Authorization (RMA) number. This number is crucial for tracking your repair and ensuring efficient processing.
Proper packaging is paramount to prevent further damage during shipping. Use the original packaging if available, or a sturdy box with ample cushioning material, such as bubble wrap or foam, to protect the controller from impact. Include all relevant accessories, such as the power cord and any affected compression garments, to aid in the diagnosis. A detailed description of the problem, including any error messages or unusual behavior, should be included with the controller.
Clearly mark the RMA number on the outside of the box to expedite processing upon arrival at the service center. Ship the package to the address provided by Covidien’s technical support, using a reputable carrier with tracking capabilities. Keep a record of the tracking number for your reference. Once the controller is received, Covidien will assess the issue and provide a repair estimate. Upon completion of the service, the controller will be returned to you, ready for continued use in preventing deep vein thrombosis.